Skip to main content
  • Material

    Porcelain tiles

  • Tile Thickness

    12 – 20 mm

  • Fixation Type

    Invisible fixation

  • Tile Preparation

    Edge groove extends along the full tile width

  • Fixing System

    Continuous horizontal aluminum profiles inserted into grooves

  • Substructure Profiles

    L- and T-shaped vertical aluminum profiles

  • Tile Orientation

    Vertical or horizontal

  • Tile Compatibility
    Pre-grooved tiles or grooved on-site using slotting machine
  • Recommended Joint Width

    10 mm

Kerf System – Porcelain Tiles

Designed for 12–20 mm porcelain tiles, this concealed fixing system uses continuous horizontal aluminum profiles inserted into full-width kerfs along tile edges. The result is a seamless, fastener-free façade ideal for applications requiring clean lines, structural safety, and long-term durability.The system supports both vertical and horizontal layouts and works with pre-grooved or on-site slotted tiles. Compatible with various substructure configurations, it enables efficient installation and easy tile replacement. As a dry mechanical system, it reduces environmental impact and withstands wind, thermal movement, and structural stress—ensuring lasting alignment and visual uniformity.

Performance Characteristics

  • Designed for use with 12 mm and 20 mm porcelain tiles
  • Kerf groove installation provides concealed, clean fixing
  • Optional bonding with polyurethane
  • Allows for custom slab dimensions through cutting or prefabrication
  • Dry installation system with optional polyurethane use
  • Supports both horizontal and vertical layouts
  • Enables easy tiles replacement
  • Accommodates wind loads, thermal expansion, and local code compliance
  • Suitable for both standard and complex façade geometries

Component Breakdown

  1. Structural Support Wall: Concrete, CMU, or framed substrate (not supplied)
  2. Waterproofing Layer: Protects wall assembly from moisture (not supplied)
  3. Thermal Insulation: Installed behind the substructure for energy efficiency (not supplied)
  4. Mechanical Anchors: Secure brackets to the structural wall
  5.  Thermal Break Pads: Minimize thermal bridging and galvanic reactions
  6. Aluminum Brackets: L-shaped, define cavity depth and support vertical profiles
  7. Vertical Aluminum Profiles: L- or T-shaped vertical profiles supporting kerf fixings
  8. Kerf Continuous Profiles: Profiles inserted into the upper and lower tile grooves for concealed fixing
  9. Porcelain Tiles : 12 mm or 20 mm thick porcelain tiles or slabs featuring full-width edge grooves for kerf fixing

starting and crowning of the façade

outside corner

inside corner

facade and celing corner

window frame

window frame and sill