Skip to main content
  • Material

    Extruded porcelain tiles

  • Tile Thickness

    20 mm

  • Fixation Type

    Invisible fixation

  • Tile Preparation

    Factory-formed edge groove across full tile width

  • Fixing System

    Horizontal aluminum profiles; EPDM on tile back for hidden vibration absorption

  • Substructure Profiles

    L- and T- vertical aluminum profiles

  • Tile Orientation

    Horizontal installation recommended

  • Recommended Joint Width

    10 mm

  • Special Feature

    Pre-grooved edge—no on-site cutting required

Extruded Porcelain Kerf System with EPDM

This concealed mechanical system is designed for 20 mm extruded porcelain tiles with factory-formed edge grooves. Tiles are secured via continuous horizontal aluminum profiles and a rear EPDM strip, which cushions against vibrations and allows for system flexibility.Ideal for horizontal tile installations, the system delivers a clean, fastener-free finish with precise alignment. As a dry mechanical method, it eliminates the need for adhesives, reducing environmental impact. Engineered for wind resistance, thermal expansion, and structural stress, it ensures long-term performance and joint stability.

Performance Characteristics

  • Vertical aluminum L- and T-profiles with adjustable bracket heights
  • Compatible with 20 mm pre-grooved ceramic panels
  • Simple, tool-free panel replacement without disturbing adjacent units
  • Wind-load tested and structurally optimized for safety and code compliance
  • Factory-made kerf grooves enable clean, concealed mechanical fixing
  • Concealed blade-type clips for a seamless, clean façade face
  • EPDM gaskets that absorb vibration and ensure water-tightness
  • Supports only horizontal tile installation
  • Tiles replacement is possible depending on fixing layout
  • Suitable for both standard and complex façade geometries
  • Optimized for efficient installation and long-term façade performance

Component Breakdown

  1. Structural Support Wall Concrete, CMU, or framed substrate (not supplied)
  2. Waterproofing Layer Moisture protection for the wall assembly (not supplied)
  3. Thermal Insulation Placed behind substructure for improved energy efficiency (not supplied)
  4. Mechanical Anchors Fix aluminum brackets to the supporting wall
  5. Thermal Break Pads Reduce thermal bridging and prevent galvanic reactions
  6. Aluminum Brackets L-shaped, used to define cavity depth and support vertical profiles
  7. Vertical Aluminum Profiles L- or T-shaped profiles supporting horizontal kerf fixings
  8. Kerf Continuous Profiles Horizontal profiles inserted into upper and lower tile grooves for concealed fixing
  9. Extruded Porcelain Tiles 20 mm thick tiles with factory-integrated full-width edge grooves
  10. EPDM gasket hidden on the back of the tile to absorb vibrations and adjust minor tolerances.

starting and crowning of the façade

outside corner

inside corner

facade and celing corner

window frame

window frame and sill